Основные характеристики
| Применение
|
SD 300 pH
Возможности SD 300 pH
Min / Max Value Memory highest and lowest measured value is saved.
Auto Hold freeze and display measurement.
Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)
Additional Display for pH Electrode and Battery Bar graph display
Low Battery Display “BAT” Automatic Temperature Compensation
Automatic Temperature Compensation (ATC) in pH mode (in the range of 0 – 105 °C) when the temperature probe is connected. Temperature can be input manually, when the temperature probe is not attached.
pH Calibration Automatic Buffer Recognition. Permissible electrodes’ data: Asymmetry: ±55mV/Slope:45…62mV/pH The condition of pH Electrode is checked at each calibration. 1, 2 or 3 point calibration with Lovibond®Standard Buffer, DIN 19266 Buffer or any manually entered Buffer values.
Redox Measurement (ORP) 2 options: “mV” Standard Redox or mV measurement “mVH” Conversion to hydrogen systems according to DIN38404 Part 6
rH Measurement The rH value is calculated from a measured Redox value and a manually input pH valu
Комплект поставки
Номер для заказа: 724600 SD 300 pH с электродом, с батарейками, защитный чехол, руководство, гарантийный талон
Номер для заказа: 724610 SD 300 pH (Набор 1) прибор, батарейки, pH/темп. пластиковый электрод тип 230, pH-буферный набор (pH 4.00/7.00/10.00), в кейсе, руководство, гарантийный талон
Номер для заказа: 724611 SD 300 pH (Набор 2) как набор 1, но с pH / температурным пластиковым электродом тип 225, сенсор температуры Pt 1000, руководство, гарантийный талон
Assessories
Order code | Article |
721230BNC | pH/temp.-electrode type 230 plastic/gel/temperature NTC30kOhm (SET 1) |
721225BNC | pH-electrode plastic/gel-type 225 (SET 2) |
721235BNC | pH-electrode glass/gel-type 235 |
721240BNC | Redox-electrode plastic-type 240 |
72 12 45 | PT1000Temperature sensor (SET 2) |
41 86 09 | KCl-solution, 3 molar saturated with AgCl, 100 ml |
72 12 50 | pH buffer-set 4.00/7.00/10.00 (25°C) |
72 12 52 | pH buffer 4.00 (25°C) 1 litre |
72 12 54 | pH buffer 7.00 (25°C) 1 litre |
72 12 56 | pH buffer 10.00 (25°C) 1 litre |
19 50 70 | Redox calibration solution, 470 mV, 100 ml |
72 46 20 | USB 300 cable, for connection to a computer |
72 46 25 | GSOFT 3050 data transmission software with logger for setting, reading and printing of stored data |
72 50 60 | Case with foam inlet |
SD 320 Con
Features SD 320 Con
Min / Max Value Memory highest and lowest measured value is saved
Auto Hold freeze and display measurement
Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)
Low Battery Display “BAT”
Automatic temperature compensation As conductivity depends strongly on temperature, each conductivity value is only valid at the corresponding temperature. Therefore the device supports temperature compensation, i.e. referring the conductivity to a reference temperature (selectable: 20 °C or 25 °C).
Salinity measurement Salinity means the sum of amount of all dissolved salts in water. The unit is g / kg.
TDS measurement (total dissolved solids) TDS means the mass concentration of dissolved media in a liquid. The unit is mg/l.
Комплект поставки
Номер для заказа: 72 47 00 SD 320 Con (Набор 1)
прибор, батарейки, кондуктометрическая ячейка LC 12 (диапазон измерения 0 – 200 mS), руководство, гарантийный талон, кейс
Номер для заказа: 72 47 20 SD 320 Con (Набор 2) прибор, батарейки, кондуктометрическая ячейка cell LC 16 (дипазон измерения 0 – 1000 mS), руководство, гарантийный талон, кейс
Assessories
Order code | Article |
19805040 | Conductivity cell LC 12, measuring range 0 – 200 mS |
19805040 | Conductivity cell LC 16, measuring range 0 – 1000 mS |
72 22 50 | Calibration solution 1413 µS/cm |
72 46 20 | USB 300 cable, for connection to a computer |
72 46 25 | GSOFT 3050 data transmission software with logger for setting, reading and printing of stored data |
72 50 60 | Case with foam inlet |